Flowjet Cleaning Equipment LTD offer more than just a range of standard cleaning equipment. We also make bespoke industrial cleaning equipment for specific cleaning applications. Flowjet offers repairs or maintenance of your pressure washer, whichever make or model. We work closely with Nilfisk, DTE, IPC & Dirt Driver and also Dema.
The ST-83 disinfection cold fogging device is perfect for disinfection, humidification, cooling, odor neutralization, pest control, mold treatment and dust deposition. The cold disinfection device can be placed in a room on its own. The cold mist spreads throughout the room and penetrates even the smallest cracks. The device comes with two nozzle inserts, one for better swirling suitable in smaller rooms such as passenger compartments. The other nozzle has a larger throw range for the treatment of entire rooms or for targeted treatment at the air intake of ventilation systems. A compressed air connection is required, the air inlet is a series 25 probe.
IMPORTANT INFORMATION
There are two nozzles included with the ST-83. A swirl nozzle and straight nozzle, below is a guide as to the settings to be used for each nozzle. It is extremely important to have the pressure correctly set. If the pressure is too low you will not get the required venturi effect to lift any liquid for effective fogging. If the pressure is too high, the air pressure will overcome the venturi effect. Both scenario's will reduce the devices ability to fog correctly.
SWIRL NOZZLE: Min: 2 bar, Max : 5 bar, Optimum: 4 bar
STRAIGHT NOZZLE : Min: 0.5 bar, Max 4 bar, Optimum: 2 bar
Stainless steel / plastic.
Safe application for disinfection.
Minimum required pressure is 3 bar.
Air connection is required.
30 Microns Max